Prikaz osnovnih podataka o dokumentu

dc.creatorLazarević, J. J.
dc.creatorRalević, U.
dc.creatorKukolj, Tamara
dc.creatorBugarski, Diana
dc.creatorLazarević, N.
dc.creatorBugarski, Branko
dc.creatorPopović, Z., V
dc.date.accessioned2021-04-20T13:04:25Z
dc.date.available2021-04-20T13:04:25Z
dc.date.issued2019
dc.identifier.issn1386-1425
dc.identifier.urihttp://rimi.imi.bg.ac.rs/handle/123456789/966
dc.description.abstractIn investigation of (patho)physiological processes, cells represent frequently used analyte as an exceptional source of information. However, spectroscopic analysis of live cells is still very seldom in clinics, as well as in research studies. Among others, the reasons are long acquisition time during which autolysis process is activated, necessity of specified technical equipment, and inability to perform analysis in a moment of sample preparation. Hence, an optimal method of preserving cells in the existing state is of extreme importance, having in mind that selection of fixative is cell lineage dependent. In this study, two commonly used chemical fixatives, formaldehyde and methanol, are used for preserving primary mesenchymal stem cells extracted from periodontal ligament, which are valuable cell source for reconstructive dentistry. By means of Raman spectroscopy, cell samples were probed and the impact of these fixatives on their Raman response was analyzed and compared. Different chemical mechanisms are the core processes of formaldehyde and methanol fixation and certain Raman bands are shifted and/or of changed intensity when Raman spectra of cells fixed in that manner are compared. In order to get clearer picture, comprehensive statistical analysis was performed.en
dc.publisherPergamon-Elsevier Science Ltd, Oxford
dc.relationinfo:eu-repo/grantAgreement/MESTD/Integrated and Interdisciplinary Research (IIR or III)/46010/RS//
dc.relationinfo:eu-repo/grantAgreement/MESTD/Integrated and Interdisciplinary Research (IIR or III)/45018/RS//
dc.relationinfo:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/175062/RS//
dc.relationinfo:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/171005/RS//
dc.rightsrestrictedAccess
dc.sourceSpectrochimica Acta Part A-Molecular & Biomolecular Spectroscopy
dc.subjectRaman spectroscopyen
dc.subjectStem cellsen
dc.subjectChemical fixationen
dc.titleInfluence of chemical fixation process on primary mesenchymal stem cells evidenced by Raman spectroscopyen
dc.typearticle
dc.rights.licenseARR
dc.citation.epage178
dc.citation.other216: 173-178
dc.citation.rankM21
dc.citation.spage173
dc.citation.volume216
dc.identifier.doi10.1016/j.saa.2019.03.012
dc.identifier.pmid30897378
dc.identifier.scopus2-s2.0-85062988764
dc.identifier.wos000471317300021
dc.type.versionpublishedVersion


Dokumenti

Thumbnail

Ovaj dokument se pojavljuje u sledećim kolekcijama

Prikaz osnovnih podataka o dokumentu