The use of single-donor fibrin glue prepared by recycled cryoprecipitation in experimental liver surgery
Authorized Users Only
2002
Authors
Balint, Bela
Cernak, I

Petakov, Marijana
Bugarski, Diana

Malicević, Z
Mandić-Radić, S
Taseski, Jovan
Article (Published version)

Metadata
Show full item recordAbstract
The purpose of the study was to evaluate the hemostatic effectiveness of fibrin glue (FG) prepared by a modification of cryoprecipitation technique in experimental rat liver surgery. FG component I was prepared by triple or 'recycled' cryoprecipitation method from single-donor plasma. Rats subjected to liver incision, partial and total lobectomy were treated with FG on the surgical cut surface or underwent standard surgical technique. The efficacy of FG-treatment was evaluated on the basis of the 24-hour survival ratio and peripheral blood hematological parameters. The mean values of fibrinogen, FXIII, fibronectin and horizontal tensile strength of FG were 54.2 +/- 19.9 g/l, 13.5 +/- 3.6 IU/ml, 3103.1 +/- 148.9 mg/l, and 1.076 +/- 0.18 N/cm(2), respectively. The survival of FG-treated rats subjected to partial and total lobectomy was significantly higher in comparison to the FG-nontreated animals, accompanied with higher values of red blood cell counts, hemoglobin concentration and hem...atocrit. When liver incision was performed, although there were no differences in survival rate, FG-treated animals had significantly higher values of the tested hematological parameters. The presented results demonstrated that by using 'recycled' cryoprecipitation it is possible to obtain high quality single-donor FG with successful hemostatic therapeutical effects, as confirmed in the experimental rat model of liver surgery.
Keywords:
cryoprecipitation / fibrin glue / single-donor / ratSource:
Haematologia, 2002, 32, 2, 135-145Publisher:
- Vsp Bv, Leiden
DOI: 10.1163/156855902320387970
ISSN: 0017-6559
PubMed: 12412733
WoS: 000178860600005
Scopus: 2-s2.0-12244275968
Collections
Institution/Community
Institut za medicinska istraživanjaTY - JOUR AU - Balint, Bela AU - Cernak, I AU - Petakov, Marijana AU - Bugarski, Diana AU - Malicević, Z AU - Mandić-Radić, S AU - Taseski, Jovan PY - 2002 UR - http://rimi.imi.bg.ac.rs/handle/123456789/74 AB - The purpose of the study was to evaluate the hemostatic effectiveness of fibrin glue (FG) prepared by a modification of cryoprecipitation technique in experimental rat liver surgery. FG component I was prepared by triple or 'recycled' cryoprecipitation method from single-donor plasma. Rats subjected to liver incision, partial and total lobectomy were treated with FG on the surgical cut surface or underwent standard surgical technique. The efficacy of FG-treatment was evaluated on the basis of the 24-hour survival ratio and peripheral blood hematological parameters. The mean values of fibrinogen, FXIII, fibronectin and horizontal tensile strength of FG were 54.2 +/- 19.9 g/l, 13.5 +/- 3.6 IU/ml, 3103.1 +/- 148.9 mg/l, and 1.076 +/- 0.18 N/cm(2), respectively. The survival of FG-treated rats subjected to partial and total lobectomy was significantly higher in comparison to the FG-nontreated animals, accompanied with higher values of red blood cell counts, hemoglobin concentration and hematocrit. When liver incision was performed, although there were no differences in survival rate, FG-treated animals had significantly higher values of the tested hematological parameters. The presented results demonstrated that by using 'recycled' cryoprecipitation it is possible to obtain high quality single-donor FG with successful hemostatic therapeutical effects, as confirmed in the experimental rat model of liver surgery. PB - Vsp Bv, Leiden T2 - Haematologia T1 - The use of single-donor fibrin glue prepared by recycled cryoprecipitation in experimental liver surgery EP - 145 IS - 2 SP - 135 VL - 32 DO - 10.1163/156855902320387970 UR - conv_1437 ER -
@article{ author = "Balint, Bela and Cernak, I and Petakov, Marijana and Bugarski, Diana and Malicević, Z and Mandić-Radić, S and Taseski, Jovan", year = "2002", abstract = "The purpose of the study was to evaluate the hemostatic effectiveness of fibrin glue (FG) prepared by a modification of cryoprecipitation technique in experimental rat liver surgery. FG component I was prepared by triple or 'recycled' cryoprecipitation method from single-donor plasma. Rats subjected to liver incision, partial and total lobectomy were treated with FG on the surgical cut surface or underwent standard surgical technique. The efficacy of FG-treatment was evaluated on the basis of the 24-hour survival ratio and peripheral blood hematological parameters. The mean values of fibrinogen, FXIII, fibronectin and horizontal tensile strength of FG were 54.2 +/- 19.9 g/l, 13.5 +/- 3.6 IU/ml, 3103.1 +/- 148.9 mg/l, and 1.076 +/- 0.18 N/cm(2), respectively. The survival of FG-treated rats subjected to partial and total lobectomy was significantly higher in comparison to the FG-nontreated animals, accompanied with higher values of red blood cell counts, hemoglobin concentration and hematocrit. When liver incision was performed, although there were no differences in survival rate, FG-treated animals had significantly higher values of the tested hematological parameters. The presented results demonstrated that by using 'recycled' cryoprecipitation it is possible to obtain high quality single-donor FG with successful hemostatic therapeutical effects, as confirmed in the experimental rat model of liver surgery.", publisher = "Vsp Bv, Leiden", journal = "Haematologia", title = "The use of single-donor fibrin glue prepared by recycled cryoprecipitation in experimental liver surgery", pages = "145-135", number = "2", volume = "32", doi = "10.1163/156855902320387970", url = "conv_1437" }
Balint, B., Cernak, I., Petakov, M., Bugarski, D., Malicević, Z., Mandić-Radić, S.,& Taseski, J.. (2002). The use of single-donor fibrin glue prepared by recycled cryoprecipitation in experimental liver surgery. in Haematologia Vsp Bv, Leiden., 32(2), 135-145. https://doi.org/10.1163/156855902320387970 conv_1437
Balint B, Cernak I, Petakov M, Bugarski D, Malicević Z, Mandić-Radić S, Taseski J. The use of single-donor fibrin glue prepared by recycled cryoprecipitation in experimental liver surgery. in Haematologia. 2002;32(2):135-145. doi:10.1163/156855902320387970 conv_1437 .
Balint, Bela, Cernak, I, Petakov, Marijana, Bugarski, Diana, Malicević, Z, Mandić-Radić, S, Taseski, Jovan, "The use of single-donor fibrin glue prepared by recycled cryoprecipitation in experimental liver surgery" in Haematologia, 32, no. 2 (2002):135-145, https://doi.org/10.1163/156855902320387970 ., conv_1437 .