Приказ основних података о документу

dc.creatorDimić, Ivana D.
dc.creatorCvijovic-Alagić, Ivana L. J.
dc.creatorKostić, Ivana
dc.creatorPeric-Grujić, Aleksandra A.
dc.creatorRakin, Marko P.
dc.creatorPutić, Slavisa S.
dc.creatorBugarski, Branko
dc.date.accessioned2021-04-20T12:36:38Z
dc.date.available2021-04-20T12:36:38Z
dc.date.issued2014
dc.identifier.issn1451-9372
dc.identifier.urihttp://rimi.imi.bg.ac.rs/handle/123456789/529
dc.description.abstractMetallic biomaterials, which are mainly used for the damaged hard tissue replacements, are materials with high strength, excellent toughness and good wear resistance. The disadvantages of metals as implant materials are their susceptibility to corrosion, the elastic modulus mismatch between metals and human hard tissues, relatively high density and metallic ion release, which can cause serious health problems. The aim of this study was to examine metallic ion release from Co-Cr-Mo alloy in artificial saliva. In that purpose, alloy samples were immersed into artificial saliva with different pH values (4.0, 5.5 and 7.5). After a certain immersion period (1, 3 and 6 weeks) the concentrations of released ions were determined using inductively coupled plasma-mass spectrometry (ICP-MS). The research findings were used in order to define the dependence between the concentration of released metallic ions, artificial saliva pH values and immersion time. The determined released metallic ions concentrations were compared with literature data in order to describe and better understand the phenomenon of metallic ion release from the biocom-patible cobalt-based alloy.en
dc.publisherSavez hemijskih inženjera, Beograd
dc.relationinfo:eu-repo/grantAgreement/MESTD/Integrated and Interdisciplinary Research (IIR or III)/46010/RS//
dc.relationinfo:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/174004/RS//
dc.rightsopenAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceChemical Industry & Chemical Engineering Quarterly
dc.subjectmetallic biomaterialsen
dc.subjectcobalt-based alloyen
dc.subjection releaseen
dc.subjectartificial salivaen
dc.subjectpH valueen
dc.titleMetallic ion release from biocompatible cobalt-based alloyen
dc.typearticle
dc.rights.licenseBY-NC-ND
dc.citation.epage577
dc.citation.issue4
dc.citation.other20(4): 571-577
dc.citation.rankM23
dc.citation.spage571
dc.citation.volume20
dc.identifier.doi10.2298/CICEQ130813039D
dc.identifier.fulltexthttp://rimi.imi.bg.ac.rs/bitstream/id/401/526.pdf
dc.identifier.scopus2-s2.0-84919415729
dc.identifier.wos000346826300013
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу