Reliability of modified clinical test of influence of sensor interactions on postural stability of athletes aged 10 to 12
Pouzdanost modifikovanog kliničkog testa uticaja senzornih interakcija na posturalnu stabilnost sportista uzrasta od 10 do 12 godina

2008
Authors
Banićević, DraganMarković, Srđan
Pažin, Nemanja
Božić, Predrag
Radovanović, Saša M.

Mirkov, Dragan M.

Article (Published version)

Metadata
Show full item recordAbstract
Based on the literature, reports about bilateral stance assessments based on force plate measurements in elementary schoolchildren and athletes are limited. The present study was designed to report reliability values for postural stability in 10 to 12 years old athletes using the Balance Master system. Twenty young athletes who regularly practice their sport activities at least three times per week, participated in the reproducibility study (mean age 11.4±1.0). The modified clinical test of sensory interaction on balance (mCTSIB) quantified children's static standing balance. Intraclass correlation and Cronbach's alpha coefficients for three repeated measures reliability of the four sensory conditions of the mCTSIB showed good to excellent reliability, ranged between 0.772 and 0.949. Reproducibility was assessed with one way ANOVA with replication and non statistical differences among three measurements were recorded. Based on the obtained findings, it could be concluded that applied ...tests can be used in reliable assessment of standing balance in 10 to 12 age athletes. .
Kratak naslov: Statička posturalna stabilnost sportista uzrasta od 10 do 12 godina. Na osnovu pregleda literature, može se zaključiti da o primeni kompjuterizovane posturografije u proceni posturalnog statusa dece i sportista nema dovoljno podataka. Zbog toga je osmišljeno istraživanje kojim je ispitana pouzdanost testa za procenu posturalnog statusa sportista uzrasta 10 do 12 godina, primenom kompjuterizovane posturografije. U istraživanju je učestvovalo 40 dečaka starosti 11,4 (±1.0) godina, koji se aktivno (bar tri puta nedeljno) bave nekim sportom. Za procenu sposobnosti održavanja posturalne stabilnosti, korišćen je tzv. modifikovani klinički test uticaja senzornih informacija na ravnotežu. Intraklas korelacioni koeficijent i krombah alfa koeficijent za tri ponovljena merenja bili su u intervalu od 0,772 do 0,949. Ponovljivost testa proveravana je jednofaktorskom analizom varijanse sa ponavljanjem za tri uzastopna merenja i nisu dobijene statistički značajne razlike. Dobijeni rez...ultati ukazuju da su evaluirani testovi za procenu posturalne stabilnosti pouzdani, te se mogu koristiti u proceni ravnoteže kod sportista uzrasta od 10 do 12 godina.
Keywords:
reproducibility / balance / center of mass / center of pressure / ponovljivost / ravnoteža / centar mase / centar pritiskaSource:
Godišnjak Fakulteta sporta i fizičkog vaspitanja, 2008, 15, 100-110Publisher:
- Univerzitet u Beogradu - Fakultet sporta i fizičkog vaspitanja, Beograd
Collections
Institution/Community
Institut za medicinska istraživanjaTY - JOUR AU - Banićević, Dragan AU - Marković, Srđan AU - Pažin, Nemanja AU - Božić, Predrag AU - Radovanović, Saša M. AU - Mirkov, Dragan M. PY - 2008 UR - http://rimi.imi.bg.ac.rs/handle/123456789/214 AB - Based on the literature, reports about bilateral stance assessments based on force plate measurements in elementary schoolchildren and athletes are limited. The present study was designed to report reliability values for postural stability in 10 to 12 years old athletes using the Balance Master system. Twenty young athletes who regularly practice their sport activities at least three times per week, participated in the reproducibility study (mean age 11.4±1.0). The modified clinical test of sensory interaction on balance (mCTSIB) quantified children's static standing balance. Intraclass correlation and Cronbach's alpha coefficients for three repeated measures reliability of the four sensory conditions of the mCTSIB showed good to excellent reliability, ranged between 0.772 and 0.949. Reproducibility was assessed with one way ANOVA with replication and non statistical differences among three measurements were recorded. Based on the obtained findings, it could be concluded that applied tests can be used in reliable assessment of standing balance in 10 to 12 age athletes. . AB - Kratak naslov: Statička posturalna stabilnost sportista uzrasta od 10 do 12 godina. Na osnovu pregleda literature, može se zaključiti da o primeni kompjuterizovane posturografije u proceni posturalnog statusa dece i sportista nema dovoljno podataka. Zbog toga je osmišljeno istraživanje kojim je ispitana pouzdanost testa za procenu posturalnog statusa sportista uzrasta 10 do 12 godina, primenom kompjuterizovane posturografije. U istraživanju je učestvovalo 40 dečaka starosti 11,4 (±1.0) godina, koji se aktivno (bar tri puta nedeljno) bave nekim sportom. Za procenu sposobnosti održavanja posturalne stabilnosti, korišćen je tzv. modifikovani klinički test uticaja senzornih informacija na ravnotežu. Intraklas korelacioni koeficijent i krombah alfa koeficijent za tri ponovljena merenja bili su u intervalu od 0,772 do 0,949. Ponovljivost testa proveravana je jednofaktorskom analizom varijanse sa ponavljanjem za tri uzastopna merenja i nisu dobijene statistički značajne razlike. Dobijeni rezultati ukazuju da su evaluirani testovi za procenu posturalne stabilnosti pouzdani, te se mogu koristiti u proceni ravnoteže kod sportista uzrasta od 10 do 12 godina. PB - Univerzitet u Beogradu - Fakultet sporta i fizičkog vaspitanja, Beograd T2 - Godišnjak Fakulteta sporta i fizičkog vaspitanja T1 - Reliability of modified clinical test of influence of sensor interactions on postural stability of athletes aged 10 to 12 T1 - Pouzdanost modifikovanog kliničkog testa uticaja senzornih interakcija na posturalnu stabilnost sportista uzrasta od 10 do 12 godina EP - 110 IS - 15 SP - 100 UR - conv_1224 ER -
@article{ author = "Banićević, Dragan and Marković, Srđan and Pažin, Nemanja and Božić, Predrag and Radovanović, Saša M. and Mirkov, Dragan M.", year = "2008", abstract = "Based on the literature, reports about bilateral stance assessments based on force plate measurements in elementary schoolchildren and athletes are limited. The present study was designed to report reliability values for postural stability in 10 to 12 years old athletes using the Balance Master system. Twenty young athletes who regularly practice their sport activities at least three times per week, participated in the reproducibility study (mean age 11.4±1.0). The modified clinical test of sensory interaction on balance (mCTSIB) quantified children's static standing balance. Intraclass correlation and Cronbach's alpha coefficients for three repeated measures reliability of the four sensory conditions of the mCTSIB showed good to excellent reliability, ranged between 0.772 and 0.949. Reproducibility was assessed with one way ANOVA with replication and non statistical differences among three measurements were recorded. Based on the obtained findings, it could be concluded that applied tests can be used in reliable assessment of standing balance in 10 to 12 age athletes. ., Kratak naslov: Statička posturalna stabilnost sportista uzrasta od 10 do 12 godina. Na osnovu pregleda literature, može se zaključiti da o primeni kompjuterizovane posturografije u proceni posturalnog statusa dece i sportista nema dovoljno podataka. Zbog toga je osmišljeno istraživanje kojim je ispitana pouzdanost testa za procenu posturalnog statusa sportista uzrasta 10 do 12 godina, primenom kompjuterizovane posturografije. U istraživanju je učestvovalo 40 dečaka starosti 11,4 (±1.0) godina, koji se aktivno (bar tri puta nedeljno) bave nekim sportom. Za procenu sposobnosti održavanja posturalne stabilnosti, korišćen je tzv. modifikovani klinički test uticaja senzornih informacija na ravnotežu. Intraklas korelacioni koeficijent i krombah alfa koeficijent za tri ponovljena merenja bili su u intervalu od 0,772 do 0,949. Ponovljivost testa proveravana je jednofaktorskom analizom varijanse sa ponavljanjem za tri uzastopna merenja i nisu dobijene statistički značajne razlike. Dobijeni rezultati ukazuju da su evaluirani testovi za procenu posturalne stabilnosti pouzdani, te se mogu koristiti u proceni ravnoteže kod sportista uzrasta od 10 do 12 godina.", publisher = "Univerzitet u Beogradu - Fakultet sporta i fizičkog vaspitanja, Beograd", journal = "Godišnjak Fakulteta sporta i fizičkog vaspitanja", title = "Reliability of modified clinical test of influence of sensor interactions on postural stability of athletes aged 10 to 12, Pouzdanost modifikovanog kliničkog testa uticaja senzornih interakcija na posturalnu stabilnost sportista uzrasta od 10 do 12 godina", pages = "110-100", number = "15", url = "conv_1224" }
Banićević, D., Marković, S., Pažin, N., Božić, P., Radovanović, S. M.,& Mirkov, D. M.. (2008). Reliability of modified clinical test of influence of sensor interactions on postural stability of athletes aged 10 to 12. in Godišnjak Fakulteta sporta i fizičkog vaspitanja Univerzitet u Beogradu - Fakultet sporta i fizičkog vaspitanja, Beograd.(15), 100-110. conv_1224
Banićević D, Marković S, Pažin N, Božić P, Radovanović SM, Mirkov DM. Reliability of modified clinical test of influence of sensor interactions on postural stability of athletes aged 10 to 12. in Godišnjak Fakulteta sporta i fizičkog vaspitanja. 2008;(15):100-110. conv_1224 .
Banićević, Dragan, Marković, Srđan, Pažin, Nemanja, Božić, Predrag, Radovanović, Saša M., Mirkov, Dragan M., "Reliability of modified clinical test of influence of sensor interactions on postural stability of athletes aged 10 to 12" in Godišnjak Fakulteta sporta i fizičkog vaspitanja, no. 15 (2008):100-110, conv_1224 .