dc.description.abstractThis study aimed to explore the effect of the knee angle and loading condition on the magnitude and reliability of squat jump (SJ) performance variables. Thirteen male sport sciences students performed in a random order 4 SJ types (knee angle of 80o [SJ80], 90o [SJ90], 100o [SJ100], and self-preferred [SJ(pref)]) against 3 external loads. The push-off distance (HpO), jump height (Hmax), maximum force (Fmax) and maximum power (Pmax) were obtained from force platform recordings. The HpO during the SJ(pref) (43.4 +/- 6.4 cm) was always between SJ90 (44.3 +/- 4.8 cm) and SJ100 (40.5 +/- 4.2 cm). The magnitudes of Hmax, Fmax and Pmax were comparable or higher during the SJ(pref). The increase of the knee angle was associated with larger values of Fmax and Pmax, but no significant differences were observed for Hmax. An acceptable reliability was observed for HpO (coefficient of variation [CV] lt = 5.09% and intraclass correlation coefficient [ICC] gt = 0.78), Hmax (CV lt = 6.06% and ICC gt = 0.84), Fmax (CV lt = 3.25% and ICC gt = 0.96) and Pmax (CV lt = 2.93% and ICC gt = 0.96). Reliability did not systematically differ between the 4 SJ types. In conclusion, the higher magnitudes and comparable reliability of the performance variables obtained during the SJ(pref) support its use for testing lower-body ballistic performance against different loads.en
dc.publisherRoutledge Journals, Taylor & Francis Ltd, Abingdon
dc.relationUniversity of Granada under a post-doctoral grant (perfeccionamiento de doctores)
dc.relationFPU15/03649
dc.relationinfo:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/175037/RS//
dc.relationinfo:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/175012/RS//
dc.rightsrestrictedAccess
dc.sourceSports Biomechanics
dc.subjectBallistic performanceen
dc.subjectpush-off distanceen
dc.subjectjump heighten
dc.subjectmaximum forceen
dc.subjectmaximum poweren
dc.titleMagnitude and reliability of mechanical outputs obtained during loaded squat jumps performed from different knee anglesen
dc.typearticle
dc.rights.licenseARR
dc.identifier.doi10.1080/14763141.2019.1618390
dc.identifier.pmid31232220
dc.identifier.scopus2-s2.0-85068038091
dc.identifier.wos000472834000001
dc.type.versionpublishedVersion


Документи

ДатотекеВеличинаФорматПреглед

Уз овај запис нема датотека.

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу