Toxicological Profile of Nanostructured Bone Substitute Based on Hydroxyapatite and Poly(lactide-co-glycolide) after Subchronic Oral Exposure of Rats

2020
Authors
Paraš, SmiljanaTrišić, Dijana

Mitrović-Ajtić, Olivera

Prokić, Bogomir
Drobne, Damjana

Živković, Slavoljub
Jokanović, Vukoman

Article (Published version)
Metadata
Show full item recordAbstract
Novel three-dimensional (3D) nanohydroxyapatite-PLGA scaffolds with high porosity was developed to better mimic mineral component and microstructure of natural bone. To perform a final assessment of this nanomaterial as a potential bone substitute, its toxicological profile was particularly investigated. Therefore, we performed a comet assay on human monocytes for in vitro genotoxicity investigation, and the systemic subchronic toxicity investigation on rats being per oral feed with exactly administrated extract quantities of the nano calcium hydroxyapatite covered with tiny layers of PLGA (ALBO-OS) for 120 days. Histological and stereological parameters of the liver, kidney, and spleen tissue were analyzed. Comet assay revealed low genotoxic potential, while histological analysis and stereological investigation revealed no significant changes in exposed animals when compared to controls, although the volume density of blood sinusoids and connective tissue, as well as numerical density... and number of mitosis were slightly increased. Additionally, despite the significantly increased average number of the Ki67 and slightly increased number of CD68 positive cells in the presence of ALBO-OS, immunoreactive cells proliferation was almost neglected. Blood analyses showed that all of the blood parameters in rats fed with extract nanomaterial are comparable with corresponding parameters of no feed rats, taken as blind probe. This study contributes to the toxicological profiling of ALBO-OS scaffold for potential future application in bone tissue engineering.
Keywords:
hydroxyapatite / bone substitute / genotoxicity / subchronic toxicity / biocompatibilitySource:
Nanomaterials, 2020, 10, 5, 918-Publisher:
- MDPI, Basel
Funding / projects:
- Chemical and structural designing of nanomaterials for application in medicine and tissue engineering (RS-172026)
- Slovenian Research Agency (ARRS) - Slovenia [J1-9162]
DOI: 10.3390/nano10050918
ISSN: 2079-4991
PubMed: 32397466
WoS: 000540781800101
Scopus: 2-s2.0-85085069788
Collections
Institution/Community
Institut za medicinska istraživanjaTY - JOUR AU - Paraš, Smiljana AU - Trišić, Dijana AU - Mitrović-Ajtić, Olivera AU - Prokić, Bogomir AU - Drobne, Damjana AU - Živković, Slavoljub AU - Jokanović, Vukoman PY - 2020 UR - http://rimi.imi.bg.ac.rs/handle/123456789/1062 AB - Novel three-dimensional (3D) nanohydroxyapatite-PLGA scaffolds with high porosity was developed to better mimic mineral component and microstructure of natural bone. To perform a final assessment of this nanomaterial as a potential bone substitute, its toxicological profile was particularly investigated. Therefore, we performed a comet assay on human monocytes for in vitro genotoxicity investigation, and the systemic subchronic toxicity investigation on rats being per oral feed with exactly administrated extract quantities of the nano calcium hydroxyapatite covered with tiny layers of PLGA (ALBO-OS) for 120 days. Histological and stereological parameters of the liver, kidney, and spleen tissue were analyzed. Comet assay revealed low genotoxic potential, while histological analysis and stereological investigation revealed no significant changes in exposed animals when compared to controls, although the volume density of blood sinusoids and connective tissue, as well as numerical density and number of mitosis were slightly increased. Additionally, despite the significantly increased average number of the Ki67 and slightly increased number of CD68 positive cells in the presence of ALBO-OS, immunoreactive cells proliferation was almost neglected. Blood analyses showed that all of the blood parameters in rats fed with extract nanomaterial are comparable with corresponding parameters of no feed rats, taken as blind probe. This study contributes to the toxicological profiling of ALBO-OS scaffold for potential future application in bone tissue engineering. PB - MDPI, Basel T2 - Nanomaterials T1 - Toxicological Profile of Nanostructured Bone Substitute Based on Hydroxyapatite and Poly(lactide-co-glycolide) after Subchronic Oral Exposure of Rats IS - 5 SP - 918 VL - 10 DO - 10.3390/nano10050918 UR - conv_4801 ER -
@article{ author = "Paraš, Smiljana and Trišić, Dijana and Mitrović-Ajtić, Olivera and Prokić, Bogomir and Drobne, Damjana and Živković, Slavoljub and Jokanović, Vukoman", year = "2020", abstract = "Novel three-dimensional (3D) nanohydroxyapatite-PLGA scaffolds with high porosity was developed to better mimic mineral component and microstructure of natural bone. To perform a final assessment of this nanomaterial as a potential bone substitute, its toxicological profile was particularly investigated. Therefore, we performed a comet assay on human monocytes for in vitro genotoxicity investigation, and the systemic subchronic toxicity investigation on rats being per oral feed with exactly administrated extract quantities of the nano calcium hydroxyapatite covered with tiny layers of PLGA (ALBO-OS) for 120 days. Histological and stereological parameters of the liver, kidney, and spleen tissue were analyzed. Comet assay revealed low genotoxic potential, while histological analysis and stereological investigation revealed no significant changes in exposed animals when compared to controls, although the volume density of blood sinusoids and connective tissue, as well as numerical density and number of mitosis were slightly increased. Additionally, despite the significantly increased average number of the Ki67 and slightly increased number of CD68 positive cells in the presence of ALBO-OS, immunoreactive cells proliferation was almost neglected. Blood analyses showed that all of the blood parameters in rats fed with extract nanomaterial are comparable with corresponding parameters of no feed rats, taken as blind probe. This study contributes to the toxicological profiling of ALBO-OS scaffold for potential future application in bone tissue engineering.", publisher = "MDPI, Basel", journal = "Nanomaterials", title = "Toxicological Profile of Nanostructured Bone Substitute Based on Hydroxyapatite and Poly(lactide-co-glycolide) after Subchronic Oral Exposure of Rats", number = "5", pages = "918", volume = "10", doi = "10.3390/nano10050918", url = "conv_4801" }
Paraš, S., Trišić, D., Mitrović-Ajtić, O., Prokić, B., Drobne, D., Živković, S.,& Jokanović, V.. (2020). Toxicological Profile of Nanostructured Bone Substitute Based on Hydroxyapatite and Poly(lactide-co-glycolide) after Subchronic Oral Exposure of Rats. in Nanomaterials MDPI, Basel., 10(5), 918. https://doi.org/10.3390/nano10050918 conv_4801
Paraš S, Trišić D, Mitrović-Ajtić O, Prokić B, Drobne D, Živković S, Jokanović V. Toxicological Profile of Nanostructured Bone Substitute Based on Hydroxyapatite and Poly(lactide-co-glycolide) after Subchronic Oral Exposure of Rats. in Nanomaterials. 2020;10(5):918. doi:10.3390/nano10050918 conv_4801 .
Paraš, Smiljana, Trišić, Dijana, Mitrović-Ajtić, Olivera, Prokić, Bogomir, Drobne, Damjana, Živković, Slavoljub, Jokanović, Vukoman, "Toxicological Profile of Nanostructured Bone Substitute Based on Hydroxyapatite and Poly(lactide-co-glycolide) after Subchronic Oral Exposure of Rats" in Nanomaterials, 10, no. 5 (2020):918, https://doi.org/10.3390/nano10050918 ., conv_4801 .