RIMI - Repository of the Institute for Medical Research
Institute for Medical Research
    • English
    • Српски
    • Српски (Serbia)
  • English 
    • English
    • Serbian (Cyrillic)
    • Serbian (Latin)
  • Login
View Item 
  •   RIMI
  • Institut za medicinska istraživanja
  • Radovi istraživača / Researchers' publications
  • View Item
  •   RIMI
  • Institut za medicinska istraživanja
  • Radovi istraživača / Researchers' publications
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Toxicological Profile of Nanostructured Bone Substitute Based on Hydroxyapatite and Poly(lactide-co-glycolide) after Subchronic Oral Exposure of Rats

Thumbnail
2020
1059.pdf (11.22Mb)
Authors
Paraš, Smiljana
Trišić, Dijana
Mitrović-Ajtić, Olivera
Prokić, Bogomir
Drobne, Damjana
Živković, Slavoljub
Jokanović, Vukoman
Article (Published version)
Metadata
Show full item record
Abstract
Novel three-dimensional (3D) nanohydroxyapatite-PLGA scaffolds with high porosity was developed to better mimic mineral component and microstructure of natural bone. To perform a final assessment of this nanomaterial as a potential bone substitute, its toxicological profile was particularly investigated. Therefore, we performed a comet assay on human monocytes for in vitro genotoxicity investigation, and the systemic subchronic toxicity investigation on rats being per oral feed with exactly administrated extract quantities of the nano calcium hydroxyapatite covered with tiny layers of PLGA (ALBO-OS) for 120 days. Histological and stereological parameters of the liver, kidney, and spleen tissue were analyzed. Comet assay revealed low genotoxic potential, while histological analysis and stereological investigation revealed no significant changes in exposed animals when compared to controls, although the volume density of blood sinusoids and connective tissue, as well as numerical density... and number of mitosis were slightly increased. Additionally, despite the significantly increased average number of the Ki67 and slightly increased number of CD68 positive cells in the presence of ALBO-OS, immunoreactive cells proliferation was almost neglected. Blood analyses showed that all of the blood parameters in rats fed with extract nanomaterial are comparable with corresponding parameters of no feed rats, taken as blind probe. This study contributes to the toxicological profiling of ALBO-OS scaffold for potential future application in bone tissue engineering.

Keywords:
hydroxyapatite / bone substitute / genotoxicity / subchronic toxicity / biocompatibility
Source:
Nanomaterials, 2020, 10, 5, 918-
Publisher:
  • MDPI, Basel
Funding / projects:
  • Chemical and structural designing of nanomaterials for application in medicine and tissue engineering (RS-172026)
  • Slovenian Research Agency (ARRS) - Slovenia [J1-9162]

DOI: 10.3390/nano10050918

ISSN: 2079-4991

PubMed: 32397466

WoS: 000540781800101

Scopus: 2-s2.0-85085069788
[ Google Scholar ]
3
3
URI
http://rimi.imi.bg.ac.rs/handle/123456789/1062
Collections
  • Radovi istraživača / Researchers' publications
Institution/Community
Institut za medicinska istraživanja
TY  - JOUR
AU  - Paraš, Smiljana
AU  - Trišić, Dijana
AU  - Mitrović-Ajtić, Olivera
AU  - Prokić, Bogomir
AU  - Drobne, Damjana
AU  - Živković, Slavoljub
AU  - Jokanović, Vukoman
PY  - 2020
UR  - http://rimi.imi.bg.ac.rs/handle/123456789/1062
AB  - Novel three-dimensional (3D) nanohydroxyapatite-PLGA scaffolds with high porosity was developed to better mimic mineral component and microstructure of natural bone. To perform a final assessment of this nanomaterial as a potential bone substitute, its toxicological profile was particularly investigated. Therefore, we performed a comet assay on human monocytes for in vitro genotoxicity investigation, and the systemic subchronic toxicity investigation on rats being per oral feed with exactly administrated extract quantities of the nano calcium hydroxyapatite covered with tiny layers of PLGA (ALBO-OS) for 120 days. Histological and stereological parameters of the liver, kidney, and spleen tissue were analyzed. Comet assay revealed low genotoxic potential, while histological analysis and stereological investigation revealed no significant changes in exposed animals when compared to controls, although the volume density of blood sinusoids and connective tissue, as well as numerical density and number of mitosis were slightly increased. Additionally, despite the significantly increased average number of the Ki67 and slightly increased number of CD68 positive cells in the presence of ALBO-OS, immunoreactive cells proliferation was almost neglected. Blood analyses showed that all of the blood parameters in rats fed with extract nanomaterial are comparable with corresponding parameters of no feed rats, taken as blind probe. This study contributes to the toxicological profiling of ALBO-OS scaffold for potential future application in bone tissue engineering.
PB  - MDPI, Basel
T2  - Nanomaterials
T1  - Toxicological Profile of Nanostructured Bone Substitute Based on Hydroxyapatite and Poly(lactide-co-glycolide) after Subchronic Oral Exposure of Rats
IS  - 5
SP  - 918
VL  - 10
DO  - 10.3390/nano10050918
UR  - conv_4801
ER  - 
@article{
author = "Paraš, Smiljana and Trišić, Dijana and Mitrović-Ajtić, Olivera and Prokić, Bogomir and Drobne, Damjana and Živković, Slavoljub and Jokanović, Vukoman",
year = "2020",
abstract = "Novel three-dimensional (3D) nanohydroxyapatite-PLGA scaffolds with high porosity was developed to better mimic mineral component and microstructure of natural bone. To perform a final assessment of this nanomaterial as a potential bone substitute, its toxicological profile was particularly investigated. Therefore, we performed a comet assay on human monocytes for in vitro genotoxicity investigation, and the systemic subchronic toxicity investigation on rats being per oral feed with exactly administrated extract quantities of the nano calcium hydroxyapatite covered with tiny layers of PLGA (ALBO-OS) for 120 days. Histological and stereological parameters of the liver, kidney, and spleen tissue were analyzed. Comet assay revealed low genotoxic potential, while histological analysis and stereological investigation revealed no significant changes in exposed animals when compared to controls, although the volume density of blood sinusoids and connective tissue, as well as numerical density and number of mitosis were slightly increased. Additionally, despite the significantly increased average number of the Ki67 and slightly increased number of CD68 positive cells in the presence of ALBO-OS, immunoreactive cells proliferation was almost neglected. Blood analyses showed that all of the blood parameters in rats fed with extract nanomaterial are comparable with corresponding parameters of no feed rats, taken as blind probe. This study contributes to the toxicological profiling of ALBO-OS scaffold for potential future application in bone tissue engineering.",
publisher = "MDPI, Basel",
journal = "Nanomaterials",
title = "Toxicological Profile of Nanostructured Bone Substitute Based on Hydroxyapatite and Poly(lactide-co-glycolide) after Subchronic Oral Exposure of Rats",
number = "5",
pages = "918",
volume = "10",
doi = "10.3390/nano10050918",
url = "conv_4801"
}
Paraš, S., Trišić, D., Mitrović-Ajtić, O., Prokić, B., Drobne, D., Živković, S.,& Jokanović, V.. (2020). Toxicological Profile of Nanostructured Bone Substitute Based on Hydroxyapatite and Poly(lactide-co-glycolide) after Subchronic Oral Exposure of Rats. in Nanomaterials
MDPI, Basel., 10(5), 918.
https://doi.org/10.3390/nano10050918
conv_4801
Paraš S, Trišić D, Mitrović-Ajtić O, Prokić B, Drobne D, Živković S, Jokanović V. Toxicological Profile of Nanostructured Bone Substitute Based on Hydroxyapatite and Poly(lactide-co-glycolide) after Subchronic Oral Exposure of Rats. in Nanomaterials. 2020;10(5):918.
doi:10.3390/nano10050918
conv_4801 .
Paraš, Smiljana, Trišić, Dijana, Mitrović-Ajtić, Olivera, Prokić, Bogomir, Drobne, Damjana, Živković, Slavoljub, Jokanović, Vukoman, "Toxicological Profile of Nanostructured Bone Substitute Based on Hydroxyapatite and Poly(lactide-co-glycolide) after Subchronic Oral Exposure of Rats" in Nanomaterials, 10, no. 5 (2020):918,
https://doi.org/10.3390/nano10050918 .,
conv_4801 .

DSpace software copyright © 2002-2015  DuraSpace
About RIMI | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About RIMI | Send Feedback

OpenAIRERCUB